    MULTICARE IN 3 PARAMETERS DIAGNOSTIC BUNDLE

    Brand: Multicare In
    In Vitro self-checking system MULTICARE IN Bundle with strips for Glucose - Triglycerides and Cholesterol. Special software provided for analyzing measurement data to a PC (optional). Clinical tested and certified by the Careggi Hospital and the Department of Critical Care Medicine, University of Florence, Italy.
    SKU: Multicare In Bundle
    €177.00
    €69.90
    i h

    Multicare In 3 Parameters Device Bundle with Strips

    In Vitro self-checking system MULTICARE IN Bundle with 50 strips for Glucose - 5 strips for Triglycerides and 5 strips for Cholesterol. Special software provided for analyzing measurement data to a PC (optional). Clinical tested and certified by the Careggi Hospital and the Department of Critical Care Medicine, University of Florence, Italy.

    multiCare in © is a diagnostic aid multiparameter with capillary aspiration for the determination of the following paramenters:
    Glucose
    Cholesterol
    Triglycerides
    multiCare IN has been developed to execute several determination from fingerprint simply by changing strip.
    multiCare IN is a new system dedicated to glucose, cholesterol and triglycerides monitoring in whole blood.
    multiCare IN system is using two different technologies:
    AMPEROMETRIC with multiCare IN glucose Electrodes strips
    REFLECTOMETRIC with multiCare IN cholesterol and triglycerides strips

    • Easy to use with external data-chip insertion
    • Wide Display
    • Automatic switch on by strip insertion
    • Memory capacity 500 test results
    • Indication of the average glucose level of the last 7, 14, 21, 28 days
    • Easy cleaning of optical part by the lower cover opening
    • Strip Ejection
    • Data Transfering to PC

     

    GLUCOSE ELECTRODES STRIPS

    The self-checking of the glycaemia allows the diabetic patient to have immediate information about his/her glucose level, but it must be performed only after accurate training with a physician or with a qualified technician.
    It is important to point out that the self-checking cannot be performed without constant follow up by the physician (to make up a timetable, to evaluate the results and to define a therapy).

     

    CHOLESTEROL STRIPS

    With the multiCare-in Cholesterol strips it is possible to quickly check cholesterol levels in the blood and inform the family physician to find a suitable therapy or to check-up on an existing therapy. The level of cholesterol in the blood is influenced by the diet, but also by: medicines, diabetes mellitus, pregnancy and severe illnesses.
    It is recommended to check blood cholesterol concentration on all people who are used to smoke, to drink too much alcohol and to eat fat and are over weighted or do not exercise enough.
    It is specially recommended to people who already had heart disease or with familiar cases of heart diseases before the age of 60. Perform the test at fast for at least 9 hours.

     

    TRIGLYCERIDES STRIPS

    Using the multiCare-in Triglycerides strips it is possible to quickly check triglycerides level in the blood.
    The level of triglycerides in the blood is influenced from fat feeding or from alterations of the metabolism of lipids but also from diabetes mellitus, nephrotic syndromes, pancreas problems, acute alcoholism.
    It is important to inform the family physician to find a suitable therapy or to check-up on an existing therapy.
    Perform the test when you have not had anything to eat or drink (except water) for at least 12 hours.

    Cholesterol strips With capillary aspiration.

    SAMPLE TO BE USED: fresh capillary whole blood or venous blood with K-EDTA or Li-Eparin as anticoagulant
    HEMATOCRIT RANGE: 35-50%
    RANGE OF MEASUREMENT: 130-400 mg/dl (3.9-10.3 mmol/l)
    SENSIBILITY: minimum measurable value: 150 mg/dl
    ACCURACY: Average error of Multicare system in comparison reference method is <10%;y = 1.0 x – 2.0 is linear regression obtained bymeasurements performed in an hospital.
    PRECISION: Repeatability: average imprecisionis <5%; average coefficient of variation = 2.48% was obtained by measurements performed in laboratory. Reproducibility: average imprecision is <5%; average coefficient of variation =2.79%was obtained by measurements performed in laboratory.
    AVERAGE TIME FOR READING: about 30 seconds
    TEMPERATURE RANGE FOR THE STRIP USE: 5-45°C
    EXPIRY DATE AFTER FIRST OPENING: 90 days
    STORE TEMPERATURE: 5°-30°
    SHELF LIFE: 24 months

    Triglykerides Test strips for Multicare In 3 parameters meter.

    SAMPLE TO BE USED: fresh capillary whole blood or venous blood with K-EDTA or Li-Eparin as anticoagulant
    HEMATOCRIT RANGE: 30-50%
    RANGE OF MEASUREMENT: 50-500 mg/dl (0.56-5.6 mmol/l)
    SENSIBILITY: minimum measurable value: 50 mg/dl
    ACCURACY: Average error of system in comparison reference method GPO is <10%; y = 0.99x – 1.18 is linear regression obtained by measurements performed in an hospital.
    PRECISION: Repeatability: average imprecision is <5%; average coefficient of variation = 2.46% was obtained by measurements performed in laboratory.
    Reproducibility: average imprecision is <5%; averagecoefficient of variation = 2.37% was obtained by measurements performed in laboratory.
    AVERAGE TIME FOR READING: about 30 seconds
    TEMPERATURE RANGE FOR THE STRIP USE: 5-45°C
    EXPIRY DATE AFTER FIRST OPENING: 90 days
    SHELF LIFE: 21 months

    Glucose Test strips for Multicare In 3 parameters meter.

    SAMPLE TO BE USED: fresh capillary whole blood
    HEMATOCRIT RANGE: 30-55%
    RANGE OF MEASUREMENT: 10-600 mg/dl (0.6-33.3 mmol/dl )
    SENSITIVITY: minimum measurable value: 10 mg/dl
    ACCURACY: The accuracy results abteined with multicareIN system were compared to glucose results obtained with the Hitachi Glucose Autoanalyzer
    747. Glucose level were measured on 104 fresh capillary specimens at three different clinical centers.
    Slope: 1.0071 y-intercept: -0.8296
    No. of samples: 104
    Range tested: 85-430 mg/dl
    PRECISION: multicareIN meter precision results for venous blood samples and control solutions.


    Within Run Precision
    blood av 43mg/dl CV=3.7%
    blood av 81.6mg/dl CV=2.5%
    blood av 132.6mg/dl CV=1.5%
    blood av 211.6mg/dl CV=2.8%
    blood av 318.2mg/dl CV=3.8%


    Total Precision
    Control av 50.4mg/dl CV=3.9%
    Control av 122.7mg/dl CV=2.1%
    Control av 321.7mg/dl CV=2.2%
    This study show that could be strip to strip
    standard deviation of up to 3.

    AVERAGE TIME FOR READING: <5 seconds
    TEMPERATURE RANGE FOR THE STRIP USE: 5-45°C
    EXPIRY DATE AFTER FIRST OPENING: 90 days
    SHELF LIFE: 24 months

    *
    *
    *

    Multicare In 3 Parameters Device Bundle with Strips

    In Vitro self-checking system MULTICARE IN Bundle with 50 strips for Glucose - 5 strips for Triglycerides and 5 strips for Cholesterol. Special software provided for analyzing measurement data to a PC (optional). Clinical tested and certified by the Careggi Hospital and the Department of Critical Care Medicine, University of Florence, Italy.

    multiCare in © is a diagnostic aid multiparameter with capillary aspiration for the determination of the following paramenters:
    Glucose
    Cholesterol
    Triglycerides
    multiCare IN has been developed to execute several determination from fingerprint simply by changing strip.
    multiCare IN is a new system dedicated to glucose, cholesterol and triglycerides monitoring in whole blood.
    multiCare IN system is using two different technologies:
    AMPEROMETRIC with multiCare IN glucose Electrodes strips
    REFLECTOMETRIC with multiCare IN cholesterol and triglycerides strips

    • Easy to use with external data-chip insertion
    • Wide Display
    • Automatic switch on by strip insertion
    • Memory capacity 500 test results
    • Indication of the average glucose level of the last 7, 14, 21, 28 days
    • Easy cleaning of optical part by the lower cover opening
    • Strip Ejection
    • Data Transfering to PC

     

    GLUCOSE ELECTRODES STRIPS

    The self-checking of the glycaemia allows the diabetic patient to have immediate information about his/her glucose level, but it must be performed only after accurate training with a physician or with a qualified technician.
    It is important to point out that the self-checking cannot be performed without constant follow up by the physician (to make up a timetable, to evaluate the results and to define a therapy).

     

    CHOLESTEROL STRIPS

    With the multiCare-in Cholesterol strips it is possible to quickly check cholesterol levels in the blood and inform the family physician to find a suitable therapy or to check-up on an existing therapy. The level of cholesterol in the blood is influenced by the diet, but also by: medicines, diabetes mellitus, pregnancy and severe illnesses.
    It is recommended to check blood cholesterol concentration on all people who are used to smoke, to drink too much alcohol and to eat fat and are over weighted or do not exercise enough.
    It is specially recommended to people who already had heart disease or with familiar cases of heart diseases before the age of 60. Perform the test at fast for at least 9 hours.

     

    TRIGLYCERIDES STRIPS

    Using the multiCare-in Triglycerides strips it is possible to quickly check triglycerides level in the blood.
    The level of triglycerides in the blood is influenced from fat feeding or from alterations of the metabolism of lipids but also from diabetes mellitus, nephrotic syndromes, pancreas problems, acute alcoholism.
    It is important to inform the family physician to find a suitable therapy or to check-up on an existing therapy.
    Perform the test when you have not had anything to eat or drink (except water) for at least 12 hours.

    Cholesterol strips With capillary aspiration.

    SAMPLE TO BE USED: fresh capillary whole blood or venous blood with K-EDTA or Li-Eparin as anticoagulant
    HEMATOCRIT RANGE: 35-50%
    RANGE OF MEASUREMENT: 130-400 mg/dl (3.9-10.3 mmol/l)
    SENSIBILITY: minimum measurable value: 150 mg/dl
    ACCURACY: Average error of Multicare system in comparison reference method is <10%;y = 1.0 x – 2.0 is linear regression obtained bymeasurements performed in an hospital.
    PRECISION: Repeatability: average imprecisionis <5%; average coefficient of variation = 2.48% was obtained by measurements performed in laboratory. Reproducibility: average imprecision is <5%; average coefficient of variation =2.79%was obtained by measurements performed in laboratory.
    AVERAGE TIME FOR READING: about 30 seconds
    TEMPERATURE RANGE FOR THE STRIP USE: 5-45°C
    EXPIRY DATE AFTER FIRST OPENING: 90 days
    STORE TEMPERATURE: 5°-30°
    SHELF LIFE: 24 months

    Triglykerides Test strips for Multicare In 3 parameters meter.

    SAMPLE TO BE USED: fresh capillary whole blood or venous blood with K-EDTA or Li-Eparin as anticoagulant
    HEMATOCRIT RANGE: 30-50%
    RANGE OF MEASUREMENT: 50-500 mg/dl (0.56-5.6 mmol/l)
    SENSIBILITY: minimum measurable value: 50 mg/dl
    ACCURACY: Average error of system in comparison reference method GPO is <10%; y = 0.99x – 1.18 is linear regression obtained by measurements performed in an hospital.
    PRECISION: Repeatability: average imprecision is <5%; average coefficient of variation = 2.46% was obtained by measurements performed in laboratory.
    Reproducibility: average imprecision is <5%; averagecoefficient of variation = 2.37% was obtained by measurements performed in laboratory.
    AVERAGE TIME FOR READING: about 30 seconds
    TEMPERATURE RANGE FOR THE STRIP USE: 5-45°C
    EXPIRY DATE AFTER FIRST OPENING: 90 days
    SHELF LIFE: 21 months

    Glucose Test strips for Multicare In 3 parameters meter.

    SAMPLE TO BE USED: fresh capillary whole blood
    HEMATOCRIT RANGE: 30-55%
    RANGE OF MEASUREMENT: 10-600 mg/dl (0.6-33.3 mmol/dl )
    SENSITIVITY: minimum measurable value: 10 mg/dl
    ACCURACY: The accuracy results abteined with multicareIN system were compared to glucose results obtained with the Hitachi Glucose Autoanalyzer
    747. Glucose level were measured on 104 fresh capillary specimens at three different clinical centers.
    Slope: 1.0071 y-intercept: -0.8296
    No. of samples: 104
    Range tested: 85-430 mg/dl
    PRECISION: multicareIN meter precision results for venous blood samples and control solutions.


    Within Run Precision
    blood av 43mg/dl CV=3.7%
    blood av 81.6mg/dl CV=2.5%
    blood av 132.6mg/dl CV=1.5%
    blood av 211.6mg/dl CV=2.8%
    blood av 318.2mg/dl CV=3.8%


    Total Precision
    Control av 50.4mg/dl CV=3.9%
    Control av 122.7mg/dl CV=2.1%
    Control av 321.7mg/dl CV=2.2%
    This study show that could be strip to strip
    standard deviation of up to 3.

    AVERAGE TIME FOR READING: <5 seconds
    TEMPERATURE RANGE FOR THE STRIP USE: 5-45°C
    EXPIRY DATE AFTER FIRST OPENING: 90 days
    SHELF LIFE: 24 months